HYDROCARBON MONITORING
WITH
THE PSA 10.525 SIR GALAHAD AND THE 10.515 LIQUID SAMPLING MERCURY
PRECONCENTRATION SYSTEM
Mercury and its organic and inorganic compounds are often present in natural gas and petrochemical products, feedstocks for many industrial reactions. Generally aluminium rotors and/or condensers are used. The low levels of mercury attack the aluminium components and cause stress fractures. Mercury induced corrosion on aluminium heat exchangers has resulted in several shut-downs which require costly replacement and loss of production.
P S Analytical has a reputation for providing reliable instrumentation to determine the mercury levels in natural gas. The Sir Galahad uses a purge and trap approach to collect mercury and its derivatives from the gas prior to re-vaporisation into a stream of argon and measurement by atomic fluorescence spectroscopy. The measurement of mercury in natural gas condensates has, however, presented more difficult problems, due to the nature of the product and the low levels of mercury involved. Following a joint research programme with a British University and a Malaysian Petrochemical Company, PSA developed a simple and effective method to analyse natural gas condensates reliably at levels below 1ppb of mercury. The team developed a means of analysing mercury in liquid hydrocarbons. Samples are vaporised at 400°C and then collected on a trap held at 200°C in a simple but effective procedure. The procedure has been verified both by measurement of the recovery of known levels of organomercury standards and by the analysis of various condensates, spike recoveries of the order of 100% being the norm. PSA has further developed a specific accessory for the Sir Galahad instrument; the PSA 10.515. This system vaporises the condensate sample into an argon stream over a heated Amasil® trap. The mercury and mercury compounds are retained in the trap and the hydrocarbons vented to waste. The mercury levels are quantified by transferring them via a clean argon stream to the Sir Galahad for analysis.
The
PSA 10.515 Liquid Sampling Mercury Pre-Concentration
System
with the PSA 10.525 Sir Galahad
Validation that the condensate contains less than 1ppb of mercury is provided in a simple and effective manner, quickly repaying the investment in the instrumentation. The quality of this work was rewarded by the presentation of the Royal Society of Chemistry Industrial Affairs Division Team Award for 1999. Visit our Awards page for more details.
To discuss particular requirements and for more detailed information on the above products please complete the Information Request Form.